top of page

Frequency: 50 Hz

Model: SAP3/18

SKU: ACSONS-PUMP-SAP3-18-4IN-1-5HP-1-25DIS

Flow: 3 m³/h (Rated capacity)

Head: 40 Meter – 115 Meter (Varies by stage/load configuration)


Specifications

  • Pump Type: Multi-Stage Submersible Borehole Pump (4-inch assembly)

  • Inlet / Outlet Size: 1-1/4 Inch Discharge

  • Well Diameter Compatibility: 4 Inch

  • Power Output: 1.5 HP / 1.1 kW

  • Operating Voltage: 220-240 V (Single-Phase) or 380-415 V (3-Phase) [Please verify motor configuration for your specific stock]

  • Motor Speed: 2900 RPM

  • Material Construction: Corrosion-resistant stainless steel shell with high-grade thermoplastic impellers and diffusers, engineered for efficiency and reliability in residential and small-scale applications.

  • Insulation Standard: Class F

  • Ingress Protection: IP 68 (Submersible)

  • Maximum Fluid Temperature: 35°C

  • Quality Certifications: ISO 9001 Certified


Key Applications

  • Residential Water Supply: Ideal for deep-well domestic water extraction for villas, houses, and small residential clusters.

  • Small-Scale Irrigation: Perfect for home garden watering, small nursery irrigation, and greenhouse misting systems.

  • Pressure Boosting: Effective as a borehole-to-tank pump for maintaining consistent pressure in small home water networks.

  • Small Commercial Use: Reliable for boutique hotel or small shop water requirements where flow demand is moderate but vertical lift is significant.


Installation and Use Notes

  • Piping: Use 1-1/4 inch high-density polyethylene (HDPE) or galvanized iron column piping. Given the high head capability of this pump, ensure all piping joints are leak-free and pressure-rated.

  • Electrical Protection: Use a dedicated control box with a thermal overload relay and a start/run capacitor (for single-phase models). This protects the motor from voltage fluctuations and mechanical jamming.

  • System Monitoring: It is recommended to install a low-water cutoff sensor (float switch or probe) to prevent the pump from running dry, which is the most common cause of premature motor failure in domestic wells.

  • Installation Requirements: Use a high-quality nylon or stainless steel safety rope to secure the pump. Do not use the electrical cable to support the weight of the pump during installation or maintenance.

Acsons Pump SAP3/18 4" 1.5hp 1.1/4"

Quantity

    CONTACT
    US

    Tel. +971553327944
    +971555270893
    Al Dhaid Washa Road
    Opp Al Dhaid Public Health Center
    Al Dhaid Sharjah.UAE

    VISIT
    US

    Monday - Sunday 07:30 am - 20:30 pm

    Friday 07:30 - 10:00 am

     

    TELL
    US

    Thanks for submitting!